Construction Specialties

Wall protection | Expansion joint covers | Entrance matting

1300 272 602
Menu
  • Home
  • Products
    • Acrovyn® Wall & Door Protection
      Acrovyn® Wall & Door Protection
      Acrovyn® Doors & Door Protection
      Acrovyn® Doors & Door Protection
      Acrovyn by Design® Bespoke Wall Coverings
      Acrovyn by Design® Bespoke Wall Coverings
      CS™ Expansion Joint Covers
      CS™ Expansion Joint Covers
      Architectural Louvres
      Architectural Louvres
      Exterior Solar Shading
      Exterior Solar Shading
      Architectural Grilles
      Architectural Grilles
  • Projects
  • Blog
  • Resources
    • Brochures
      Brochures
      Market Sectors
      Market Sectors
  • About Us
  • Contact
  • Careers

Loma Linda University Medical Center – California, USA

Loma Linda University Medical Center

California, USA

Loma Linda University Medical Center

California, USA

About the Project

In 1994, California passed Senate Bill 1953, which mandated stricter seismic safety standards for hospitals. The bill requires that hospitals be able to not only withstand a major quake but also continue to provide services in its aftermath. This helped put into motion a project to replace the existing Loma Linda Hospital with the $1.5 billion dual-tower Dennis and Carol Troesh Medical Campus.

Design Goals

Envisioning two healthcare buildings—a tower for children and another for adults—, architect NBBJ teamed with engineers Arup and Stantec, as well as builder McCarthy Building Co., to design towers that could withstand earthquake damage and continue operations during and immediately after extreme seismic activity.

Solution

The result is an unmatched engineering marvel. The shared five-story podium that serves as the base of the two towers can move six inches vertically and up to 42 inches laterally without suffering structural damage.

To accomplish this feat, engineers from Arup incorporated a seismically base-isolated structural system to effectively decouple the buildings from the ground beneath them. An assembly of 126 individual base isolators that use triple friction pendulum bearings allows horizontal movement, while 104 fluid viscous dampers act like shock absorbers to reduce energy transmission from the ground to the building. A “dry moat” surrounding the building gives space for the structure to remain stationary as the ground moves around and beneath it.

Large-scale expansion joint systems from Construction Specialties were designed and installed on the pedestrian bridge connecting the adult and children’s towers, allowing the structure to move adjacent to the building. Even if the buildings are moving, people can safely pass through the bridge corridor.

Watch the Case Story

What Next

GET BROCHURE
CONTACT US
REQUEST PRICING
ORDER A SAMPLE
ASK A QUESTION

Filed Under: Expansion Joint Covers, Projects

Expansion Joint Covers

cs_ejc_brochure_Page_01
  • Full product selection guide
  • Detailed technical information

1300 272 602
sales@c-sgroup.com.au
Order a Sample
Request an Estimate
Get Technical Help

Menu

  • CS Products
  • Projects
  • Blog
  • About us
  • Contact Us
  • Pick Country

Contact

Construction Specialties Australia
Unit 6, 26 Cosgrove Road
Enfield, NSW 2136
AUSTRALIA
Tel: 1300 272 602
Fax: 1300 247 407
Email: sales@c-sgroup.com.au

Privacy

This website uses cookies to help us give you the best experience when you visit our website. By continuing to use this website, you consent to our use of these cookies. Find out more about how we use cookies and how to manage them below in our privacy policy.
Privacy Policy

Construction Specialties Australia acknowledges the Traditional Custodians of the Lands on which we operate throughout Australia, and recognise their continuing connection to the land, waters and culture. We pay our respects to them and to Elders, past and present.

Copyright © 2025 · Construction Specialties

Copyright © 2025 · Genesis Framework · WordPress · Log in