Storm Resistant Louvres

US-RSH-5700

Construction Specialties Storm Resistant Louvres repel up to 100% of wind-driven rain. Available in both horizontal and vertical configurations.

Ideal when you:

  • Need 100% resistance to wind-driven rain
  • Expect winds as high as 50 mph that drive around 20mm of water per hour
  • Must integrate the louvre into the building’s total design or house them behind architectural grilles, detailing or continuous-line louvres
  • Can’t use a plenum due to cost or space considerations
  • Plan to house sensitive equipment adjacent to the louvre system
  • Need a louvre to integrate with a CENTRIA Formawall® Dimension Series® panel system

Storm Resistant Models

All louvres listed below are tested in accordance with AS/NZS 4740:2000 (R2016). Tests are conducted using full size aerodynamic test equipment.

RS-4300

Volume Flow rate (m³/s)00.511.522.533.5
RS-4300Performance LevelAABBCCDD
Effectiveness (%)10099989691917760

RS-5300

Volume Flow rate (m³/s)00.511.522.533.5
RS-5300Performance LevelAAAABBCD
Effectiveness (%)10010010099.198.396.892.678.7

RSH-5700

** Tested with higher wind speed and rainfall intensity than the requirements from the AS/NZS 4740:2000 (R2016).
Volume Flow rate (m³/s)00.511.522.533.544.55
RSH-5700Performance LevelAAAAAAAAABC
Effectiveness (%)10010010010010010099.999.599.498.194.9

RSV-5700

** Tested with higher wind speed and rainfall intensity than the requirements from the AS/NZS 4740:2000 (R2016).
Volume Flow rate (m³/s)00.511.522.533.544.55
RSV-5700Performance LevelAAAAAAAAAAA
Effectiveness (%)---------10099.8

RS-5605

** Tested with higher wind speed and rainfall intensity than the requirements from the AS/NZS 4740:2000 (R2016).
Volume Flow rate (m³/s)00.511.522.533.544.55
RS5605Performance LevelAAAAAAAAAAA
Effectiveness (%)--------99.499.399.2

Louvres

2016 Louvre Brochure
What's in the brochure
  • - Industry Leading Products
  • - Innovative New Design Options
  • - Detailed Technical Information
  • - Louvre Specification Guidance

1300 272 602
sales@c-sgroup.com.au
Order a Sample
Request an Estimate
Get Technical Help

Menu

  • CS Products
  • Projects
  • Blog
  • About us
  • Contact Us
  • Pick Country

Contact

Construction Specialties Australia
Unit 6, 26 Cosgrove Road
Enfield, NSW 2136
AUSTRALIA
Tel: 1300 272 602
Fax: 1300 247 407
Email: sales@c-sgroup.com.au

Privacy

This website uses cookies to help us give you the best experience when you visit our website. By continuing to use this website, you consent to our use of these cookies. Find out more about how we use cookies and how to manage them below in our privacy policy.
Privacy Policy

Construction Specialties Australia acknowledges the Traditional Custodians of the Lands on which we operate throughout Australia, and recognise their continuing connection to the land, waters and culture. We pay our respects to them and to Elders, past and present.

Copyright © 2025 · Construction Specialties

Copyright © 2025 · Genesis Framework · WordPress · Log in